MPPT SOLAR CHARGE CONTROLLER CIRCUIT
₹210.00 Incl. GSTThe output of the Solar Charger is intended to charge a single polymer lithium-ion cell. The load should be connected in parallel with the battery. Each Solar Charger comes equipped with a CN3791 power tracking battery charging circuit and pre-installed four 2-pin JST/PH2.0 connectors.
MPR 121 Capacitive Touch Module
₹79.00 Incl. GSTThis MPR121 is a capacitive touch sensor controller driven by an I2C interface. The chip can control up to twelve individual electrodes, as well as a simulated thirteenth electrode The MPR121 also features eight LED driving… pins, when these pins are not configured as electrodes, they may be used to drive LEDs. There a four jumpers on the bottom of the board, all of which are set (closed) by default. An address jumper ties the ADD pin to the ground, meaning the default I2C address of the chip will be 0x5A. If you need to change the address of the chip (by shorting ADD to a different pin), make sure you open the jumper first. Jumpers also connect SDA, SCL, and the interrupt pin to 10k pull-up resistors. If you do not require the pull-up resistors you can open the jumpers by cutting the trace connecting them.
MPU-6050
₹140.00 Incl. GSTThe MPU-6050 3-Axis Accelerometer and Gyro Sensor module use MPU-6050 which is a little piece of motion processing tech. The MPU6050 datasheet is available in the attachment section to get this visit.
There are different types of magnetometer are available the basic differences between MPU6000, MPU6050 and MPU6500 is:
| MPU6000 | MPU6050 | MPU6500 |
| 1. A sampling rate of 8 kHz. | 1. A sampling rate of 8 kHz. | 1. A sampling rate of 32 kHz. |
| 2. Supports SPI and I2C interface. But I2C is too slow to handle 8 kHz gyro update. | 2. Supports I2C interface communication protocol. | 2. Supports both I2C and SPI interface. |
| 3. Vibration Sensitivity is better than MPU6500. | 3. Vibration Sensitivity is better than MPU6500 but the speed of operation is less than MPU6000. | 3. It is more susceptible to vibrations, so the need for some vibration isolation methods.
It is faster than both MPU. |
The MPU6050 devices combine a 3-axis gyroscope and a 3-axis accelerometer on the same silicon together with an onboard Digital Motion Processor (DMP) capable of processing complex 9-axis MotionFusion algorithms. To get more insights about specifications visit the MPU6050 datasheet.
MQ 135
₹90.00 Incl. GSTThis is a MQ 135 Air Quality/Gas Detector Sensor Module For Arduino.
If you are want to make a device that is used to detect Ammonia, Sulphide, and Benzene steam, also sensitive to smoke and other harmful gasses from the desired distance, then this sensor is needed for you.y0u can buy this sensor from Robu.in at a reasonable price.
The MQ 135 Air Quality Detector Sensor Module For Arduino has lower conductivity in clean air. When the target combustible gas exists, the conductivity of the sensor is higher along with the gas concentration rising.
Convert the change of conductivity to the corresponding output signal of gas concentration. The MQ135 gas sensor has a high sensitivity to Ammonia, Sulphide, and Benzene steam, also sensitive to smoke and other harmful gases.
MQ-136
₹65.00 Incl. GSTMQ-136-Hydrogen Sulfide Gas Sensor can be used to monitor the concentration of Hydrogen Sulfide gas. This Module simplifies using the MQ-136 gas sensor by providing digital as well as analog output which can be interfaced to Microcontrollers, Arduino, and Raspberry pi.
The sensitive material of the MQ136 gas sensor is SnO2, which with lower conductivity in clean air. When the target Hydrogen sulfide gas exists, the sensor’s conductivity is higher along with the Hydrogen sulfide concentration rising. Please use a simple electric circuit, Convert the change of conductivity to correspond output signal of gas concentration. MQ136 gas sensor has a high sensitivity to Hydrogen sulfide, Low sensitivity for other combustible gas. It is at a low cost and suitable for different applications.
MQ-136
₹1,248.00 Incl. GSTMQ-136-Hydrogen Sulfide Gas Sensor can be used to monitor the concentration of Hydrogen Sulfide gas. This Module simplifies using the MQ-136 gas sensor by providing digital as well as analog output which can be interfaced to Microcontrollers, Arduino, and Raspberry pi.
The sensitive material of the MQ136 gas sensor is SnO2, which with lower conductivity in clean air. When the target Hydrogen sulfide gas exists, the sensor’s conductivity is higher along with the Hydrogen sulfide concentration rising. Please use a simple electric circuit, Convert the change of conductivity to correspond output signal of gas concentration. MQ136 gas sensor has a high sensitivity to Hydrogen sulfide, Low sensitivity for other combustible gas. It is at a low cost and suitable for different applications.
MQ-137
₹1,429.00 Incl. GSTThe MQ137 sensor is a gas sensor module is specially designed to detect and sense gases like ammonia (NH3) and carbon monoxide (CO). The MQ137 gas sensor module comes with digital pins that can be connected to a microcontroller like Arduino boards and come in handy when you are only trying to detect one particular gas.
Applications of MQ137 Gas Sensor
- Detector measure Gases like NH3 or CO
- Air quality monitor
- Gas leak alarm
- Safety standard maintenance
- Maintaining environmental standards in hospitals
MQ-3
₹80.00 Incl. GSTIt provides an analog output corresponding to the concentration of the gas in the air and an easy to use digital output.
The onboard potentiometer can be used to set the maximum gas concentration beyond which the digital output gets triggered. Just power the module with 5V set the threshold and you can start getting the gas concentration of the air around the sensor! An onboard LED signals the presence of any gas. Perfect sensing alcohol concentration on your breath just likes a common breathalyzer.
The digital output can be easily interfaced to microcontrollers and other circuits. The analog output can be hooked up to an ADC of a microcontroller to get a wide range of sensor readings.
MQ-4
₹94.00 Incl. GSTIf you want to detect methane gases with your projects, you will need sensors. If you need any data on the sensitive material then, the MQ-4 High Sensitivity Gas Methane (CNG) Detector Gas Sensor Module is a quite good solution.
It provides an analog output corresponding to the concentration of the gases in the air and an easy-to-use digital output. The onboard potentiometer can be used to set the maximum gas concentration beyond which the digital output gets triggered. The MQ-4 can detect natural gas concentrations anywhere from 200 to 10000ppm.
Just power the module with 5V set the threshold and you can start getting the gas concentration of the air around the sensor! An onboard LED signals the presence of any gas.
MQ-5
₹174.00 Incl. GSTThe MQ5 ( MQ-5 ) is used in gas leakage detecting equipment in consumer and industry applications, this sensor is suitable for detecting LPG, natural gas, coal gas. Avoid the noise of alcohol, cooking fumes, and cigarette smoke. The sensitivity can be adjusted by the potentiometer.
The sensitive material of the MQ-5 gas sensor is tin Oxide (SnO2), which with lower conductivity in clean air. When the target combustible gas exists, The sensor’s conductivity is higher along with the gas concentration rising. Please use a simple electro circuit, Convert the change of conductivity to the corresponding output signal of gas concentration.
MQ-5 gas sensor has a high sensitivity to Methane, Propane, and Butane, and could be used to detect both Methane and Propane. The sensor could be used to detect different combustible gas especially Methane, it is with low cost and suitable for different application
MQ-6
₹30.00 Incl. GSTMQ-6 Liquefied Petroleum Isobutane Propane Gas Sensor module is a great way to add basic gas sensing to your project at a reasonable price. TheMQ-5 Methane LPG Liquid Propane Gas Sensor Module particulate sensor uses a Buzzer to sense any detected material that is even present in the air!
This is a simple-to-use MQ-6 Liquefied Petroleum Isobutane Propane Gas Sensor module, suitable for sensing LPG (composed of mostly propane and butane) concentrations in the air. The MQ-6 can detect gas concentrations anywhere from 200 to 10000ppm. The MQ-6 Liquefied Petroleum Isobutane Propane Gas Sensor module particulate sensor uses a Potentiometer to change the detection range of the sensor!
This sensor has high sensitivity and a fast response time. The sensor’s output is an analog resistance. The drive circuit is very simple, all you need to do is power the heater coil with 5V, add a load resistance, and connect the output to an ADC.
MQ-8
₹43.00 Incl. GSTA sensitive material MQ-8 Hydrogen Gas Sensor Module H2 Alarm Detection use in clean air low conductivity tin oxide (SnO2). When there is the environment in which the combustible gas sensor, conductivity sensor with increasing concentration of combustible gases in air increases.
Using a simple circuit to convert the change in conductivity of the gas concentration corresponding to the output signal. MQ-8 hydrogen gas sensor of high sensitivity, the monitoring of the other hydrogen-containing gas is also very satisfactory.
This sensor can detect a wide range of hydrogen gas, city gas, in particular, is a low-cost sensor for a variety of applications.





BATTERY HOLDERS





AM ROBOTICS
DRONE TRANSMITER AND RECEIVER



Water Sensors